Opkon_Canbus_User_Manual

Mechanical Data 

Case Dimensions 33mm x 33mm 

Case Material Anodized Aluminium 

Rod Diameter 6mm 

Rod Material Stainless Steel 

Mechanical Life 100 million movement 

Mechanical Fixing Variable brackets 

Electrical Data 

Power Supply : 24V DC 

Current Consumption typ: 60mA at 24V DC 

Power Consumption : max. 2 W 

Protection Reverse Polarity 

Sensor Data 

Measurement Stroke 30 to 2000 mm 

Resolution 15 bit (stroke : 32767 mm) 

Linearity ±%0,05 (>200mm) , ±%0,1 (130 – 200mm), ±%0,05 ( 75 – 130mm), ±%0,5  (<75mm) 

Response Time 10 ms  

Termination 120R Configure with Software 

Interface 

Interface CAN 

Protocol CANbus 

Communication Profile CiA301,  

Node Number 1 up to 127 (default Node ID : 20) 

Baud Rate 10 Kbit/s to 1 Mbit/s (default Baud Rare : 1Mbit/s) 

Properties Asynchronous – Synchronous communication, Node ID, Baud Rate,  Termination, etc. 

Diagnostic Leds 

Green Led: Power On, Can Communication Active 

Red Led :Error, Stop Mode 

General Data 

Protection IP65 

Working Temperature Range -20°C to 80°C 

Cantidad :